Popular Searches

  • Start-up of large-power synchronous motor with the 6 kV ,
    Start-up of large-power synchronous motor with the 6 kV ,

    voltage drop In the final stage of the start-up inrush cur-rent decreases, motor voltage and motor torque increase At a speed close to the synchronous speed the reactor is short-circuited * Silesian University of Technology, Faculty of Electrical Engineering, Department of Power Electronics, Electrical Drives and Robotics.

    Know More
  • An example of calculating transformer size and voltage ,
    An example of calculating transformer size and voltage ,

    Calculate voltage drop Let’s calculate voltage drop in transformer 1000KVA, 11/0480 kV, impedance 575% due to starting of 300 kW, 460V, 08 power factor, motor code D (kva/hp) Motor starts 2 times per hour and the allowable voltage drop at transformer secondary terminal is 10%

    Know More
  • Behaviour Of Synchronous Motor On Loading | Electrical ,
    Behaviour Of Synchronous Motor On Loading | Electrical ,

    In case of synchronous motor speed always remains constant equal to the synchronous speed, irrespective of load condition It is interesting to study how synchronous motor reacts to changes in the load condition In a dc motor, armature develops an emfafter motoring action starts, which opposes supply voltage, called back emf E b

    Know More
  • Induction motor:Effect of Change in Supply Voltage on ,
    Induction motor:Effect of Change in Supply Voltage on ,

    Jun 02, 2015· A 50-Hz motor operates well on a 60-Hz line provided its terminal voltage is raised to 60/50 = 6/5 (ie120%) of the name-plate rating In that case, the new breakdown torque becomes equal to the original breakdown torque and the starting torque is only slightly reduced

    Know More
  • Synchronous Motor Copyright 2004 Kilowatt Classroom, ,
    Synchronous Motor Copyright 2004 Kilowatt Classroom, ,

    Synchronous Motors are three -phase AC motors which run at synchronous speed, without slip (In an induction motor the rotor must have some “slip” The rotor speed must be ,

    Know More
  • Induction Motor Starting Methods - Brighthub Engineering
    Induction Motor Starting Methods - Brighthub Engineering

    It is not desirable to start large motors direct on line (giving full voltage to the stator) Normally with motors beyond 5 HP, starters are provided For reduction in the starting current, a lower voltage is applied to the stator, especially for the squirrel cage induction motors Full voltage is only applied when the motor picks up speed

    Know More
  • 10 Starting Method for Induction Motors
    10 Starting Method for Induction Motors

    A 3-phase induction motor is theoretically self starting The stator of an induction motor consists of 3-phase windings, , Hz supply the synchronous speed will be 1000 and 1500 rpm respectively If the full load slip is 5% in each case, , If the stator voltage drop is neglected the terminal voltage V1 is ,

    Know More
  • Introduction to Motor Starting Analysis - CED Engineering
    Introduction to Motor Starting Analysis - CED Engineering

    Introduction to Motor Starting Analysis , during the motor starting period if the voltage drop is excessive The actual drop out voltage of industrial contactors is 60 to 70% of the rated system voltage A brief discussion of major problems associated with starting large motors, or groups

    Know More
  • Inspection and test procedures for Rotating Machinery ,
    Inspection and test procedures for Rotating Machinery ,

    Inspection and test procedures of Rotating Machinery, Synchronous Motors and Generators (On photo: Small machine test set – , Voltage drop at start 3 Bus voltage at machine full-load 4 Locked-rotor current 5 Current after synchronization but before loading 6 Current at maximum loading 7 Acceleration time to near synchronous speed

    Know More
  • Starting process of medium power line start permanent ,
    Starting process of medium power line start permanent ,

    Starting process of medium power line start permanent magnet synchronous motor Abstract The paper deals with analysis of line start permanent magnet synchronous motor start and synchronization process Four-pole 160 kW low-voltage ,

    Know More
  • TECO-WEsTinghOusE
    TECO-WEsTinghOusE

    In general, synchronous motors have less of a system voltage drop during start-up than induction motors Power factor improvement is one of the most attractive considerations in selecting a synchronous machine Synchronous motors operate at leading power factors and are typically available with rated power factors ranging from unity to 080 .

    Know More
  • What amount of voltage drop does it take to cause problems ,
    What amount of voltage drop does it take to cause problems ,

    The performance of the induction motor is severely affected by the change in supply voltage and frequency from its rated value Generally, the variation in supply voltage is allowed up to +/- 10 % of the rated voltage and variation in the frequenc.

    Know More
  • How Voltage Drop Affects the Operation of Induction Machines
    How Voltage Drop Affects the Operation of Induction Machines

    Sep 29, 2016· Voltage drop can negatively affect the performance of your induction machines Induction machines do not like voltage drop When talking about induction machines, what most people think about is the 3 phase AC induction motor For the most part, the power output of an induction machine is directly proportional to voltage and current

    Know More
  • Motor Starting Calculator – Voltage Disturbance
    Motor Starting Calculator – Voltage Disturbance

    Usually this starting current persists till the motor reaches close to its synchronous speed (rated speed) Induction motors under starting conditions have extremely low power factor of around 10-30% The combination of large starting current and poor power factor will cause large voltage drop across the system impedance

    Know More
  • Motor Starting & Control Resistors - Hilkar
    Motor Starting & Control Resistors - Hilkar

    Motor Starting Resistors are used to reduce the voltage at the motor terminals and also decrease the starting current Motor Starting Resistors are necessary because the self resistance of a motor armature is very low When the voltage is first applied, excessive current will flow

    Know More
  • III Synchronous Motors
    III Synchronous Motors

    Starts as an induction motor The synchronous motor rotor also has a squirrel-cage winding, known as an Amortisseur winding, which produces torque for motor starting Synchronous motors will run at synchronous speed in accordance with the formula: Example: the speed of a 24 -Pole Synchronous Mot or operating at 60 Hz would

    Know More
  • Run-up of Line Start Permanent Magnet Synchronous Motor in ,
    Run-up of Line Start Permanent Magnet Synchronous Motor in ,

    Jul 12, 2015· The start up is not so spectacular as in fan drive due to relatively low moment of inertia (It takes about 2 seconds) The measured inrush current was 6,5x nominal current and causes 18% voltage drop

    Know More
  • The essentials of synchronous machines in power ,
    The essentials of synchronous machines in power ,

    Nov 22, 2019· Synchronous machines can be used as generators or motors They are of 3-phase construction, even though some special exceptions can be found A bulk of the applications are within power ranges roughly varying from a megawatt level to several tenths (or even hundreds) of megawatts with rated voltages .

    Know More
  • SYNCHRONOUS MOTOR CONTROL - Electrical Part Manual S
    SYNCHRONOUS MOTOR CONTROL - Electrical Part Manual S

    improve the motor starting torque and to limit the in­ duced field voltage during starting or when the field excitation is removed The resistor current and ohmic values are determined by the motor designer IL 14-000-lC 5 The "DP" Damper Winding Protection Relay protects the damper winding of the synchronous motor

    Know More
  • actiVAR™ Provides Much Needed Voltage Support to Help ,
    actiVAR™ Provides Much Needed Voltage Support to Help ,

    Morehead, KY compressor station The compressor station had been experiencing failed motor starts due to voltage drop during starting of their 10,000 HP, 138kV synchronous motor driven compressors Background Kinder Morgan Energy Partners' Tennessee Gas Pipeline (TGP) is a 13,900mile pipeline that -

    Know More
  • Starting Large AC Motors - siteieeeorg
    Starting Large AC Motors - siteieeeorg

    the motor will develop at synchronous speed with rated voltage applied at rated , taking into account any voltage drop resulting from the starting current drawn by the machine This information and the , Synchronous Motor Typical Starting Curves Synchronous Motor 29 Synchronous Motor Stator High Speed Low Speed 30

    Know More
  • Plant efficiency benefits resulting from the use of ,
    Plant efficiency benefits resulting from the use of ,

    The most straightforward approach to synchronous motor starting is to monitor the frequency of the voltage across the field discharge resistor As the motor nears syn-chronous speed, the slip frequency approaches zero across the resistor (see Figure 8) At a specific slip frequency and rotor angle, dc is

    Know More
  • A Comparison of Induction Motor Starting Methods Being ,
    A Comparison of Induction Motor Starting Methods Being ,

    A COMPARISON OF INDUCTION MOTOR STARTING METHODS BEING POWERED BY A DIESEL-GENERATOR SET Adam Wigington, MS University of Nebraska, 2010 Adviser: Sohrab Asgarpoor Starting induction motors on isolated or weak systems is a highly dynamic process that can cause motor and load damage as well as electrical network fluctuations

    Know More
  • Motor Starting & Control Resistors - Hilkar
    Motor Starting & Control Resistors - Hilkar

    Motor Starting Resistors are used to reduce the voltage at the motor terminals and also decrease the starting current Motor Starting Resistors are necessary because the self resistance of a motor armature is very low When the voltage is ,

    Know More
  • GENERATOR SELECTION - US Forest Service
    GENERATOR SELECTION - US Forest Service

    GENERATOR SELECTION , start motors The voltage drop is higher in single phase systems for a given load for the same wire size used in 3 phase systems , there is a recovery voltage dip from 5 cycles until the motor reaches 70%-90% of synchronous speed

    Know More
  • Voltage drop calculation : Engineering : Start›Ing MV ,
    Voltage drop calculation : Engineering : Start›Ing MV ,

    Example for a voltage drop calculation We calculate for you the voltage drop which occurs when you start your motor/machine combination, if we know the configuration of your feeding grid in addition to the technical data of motor and driven machine Below you can find a typical example for a calculation 2 voltage levels (40 kV and 6 kV) are .

    Know More
  • CYME Power Engineering Software - Motor Starting Analysis
    CYME Power Engineering Software - Motor Starting Analysis

    The CYME power engineering software features an optional Motor Starting Analysis module for dynamic, locked rotor and maximum start size analysis which is dedicated to simulating the effects of induction and synchronous motor starting in three-phase electric power systems

    Know More
  • Voltage Sag due to Induction motor starting – Voltage ,
    Voltage Sag due to Induction motor starting – Voltage ,

    Apr 01, 2018· Motor Starting Voltage Drop Calculation Consider a motor connected to the utility supply through a transformer as shown X t is the transformer leakage reactance and X LR is the locked rotor reactance of the motor Since many motors windings are connected in delta, it is important to convert the reactance to its equivalent wye

    Know More
  • Maximum Statring Voltage Drop for Motors - Electric motors ,
    Maximum Statring Voltage Drop for Motors - Electric motors ,

    Oct 08, 2003· Voltage drop during a motor starting is the function of motor characteristics (LRA, subtransient reactance), starting method and source impedance Starting method may have to do with what starting torque is required So it varies by actaul field conditions

    Know More
  • Improve Motor Operation at Off-Design Voltages
    Improve Motor Operation at Off-Design Voltages

    voltage in-plant distribution systems are subject to the same NEC maximum voltage drop of 3%, these systems are usually held to well under 1% The medium voltage can be transformed down near the points of use, or the equipment can be driven by medium-voltage motors Standard medium-voltage motors are available as small as 100 horsepower

    Know More